Box 1. Summary of facilitated group discussion (round three)
ThemeKey points raised by panellists
Inappropriate use of POCTs
  • Availability does not ensure appropriate use

  • Overreliance on POCTs and testing without indication was a concern (for example, urine dipsticks in older adults, CRP, and Strep A tests)

  • POCTs should be guided by evidence-based protocols; inappropriate use alone was not grounds for excluding a test

Test accuracy
  • Concerns about insufficient sensitivity and safety of certain tests (for example, standard troponin and mononucleosis antibody POCT)

  • Limited evidence on analytic accuracy and clinical effectiveness in primary care limits informed decision making and guideline development

Clinician skills and confidence
  • Lack of confidence or training in some POCTs, especially ECG interpretation and point-of-care ultrasound

  • Use should not exceed a clinician’s competence to avoid patient safety risks

Familiarity with specific POCTs
  • Some tests (for example, blood ketones and blood lactate) were less familiar to clinicians in certain countries, potentially affecting perceived usefulness

Fee-for-service arrangements
  • Payment models could drive inappropriate POCT use if reimbursements incentivise testing outside clinical guidance

POCT availability driving demand
  • In some regions, patients seeking CRP or antigen tests unavailable in-hours specifically increased OOH demand

  • D-dimer tests sometimes used for reassurance outside guidelines, risking unnecessary further investigation

Interface with in-hours care
  • Expanded POCT availability OOH may shift work from in-hours services and increase system-level costs

  • Tests like faecal occult blood and liver function tests were excluded partly for this reason

  • CRP = C-reactive protein. ECG = electrocardiography. INR = international normalised ratio of blood coagulation. OOH = out of hours. POCT = point-of-care test. Strep A = group A Streptococcus.