Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-piece acrylic intraocular lenses

CJ Heatley, DJ Spalton, A Kumar, R Jose… - Journal of Cataract & …, 2005 - journals.lww.com
Purpose: To determine the effect of intraocular lens (IOL) material on the development of
posterior capsule opacification (PCO) at 1 year. Setting: Department of Ophthalmology, St. …

POCOman: new system for quantifying posterior capsule opacification

…, B Uyanonvara, J Boyce, C Heatley… - Journal of Cataract & …, 2004 - journals.lww.com
Purpose: To describe a new method of measuring posterior capsule opacification (PCO)
and intraocular lens (IOL) rotation and report the validation of the method. Setting: …

Steroid prophylaxis in eyes with uveitis undergoing phacoemulsification

…, DJ Spalton, L Bender, R Antcliff, C Heatley… - British journal of …, 2004 - bjo.bmj.com
Aim: To compare the efficacy of two preoperative steroid regimens for cataract surgery in
patients with uveitis. Methods: 40 uveitis patients with cataract underwent phacoemulsification …

Effect of pupil dilation on the accuracy of the IOLMaster

CJ Heatley, LA Whitefield, CE Hugkulstone - Journal of Cataract & …, 2002 - Elsevier
PURPOSE: To evaluate the effect of pupil dilation on the accuracy of the IOLMaster® (Zeiss)
in performing biometry and to assess test–retest variability without pupil dilation. SETTING: …

Intravitreal triamcinalone acetonide for refractory uveitic cystoid macular oedema: longterm management and outcome

RI Angunawela, CJ Heatley… - Acta …, 2005 - Wiley Online Library
Purpose: To establish the role of intravitreal triamcinalone acetonide (TA) in the long term
management of refractory uveitic cystoid macular oedema (CMO) and to determine the long …

Correlation between the measurement of posterior capsule opacification severity and visual function testing

RMJ Jose, LE Bender, JF Boyce, C Heatley - Journal of Cataract & …, 2005 - Elsevier
… The function maps values in f to g are in the range 0 to 255 such that g(m C ) = m T , where
m C is the mean intensity of image f within a defined masked area and m T equals 128. The …

Objective measurement of intraocular lens movement and dioptric change with a focus shift accommodating intraocular lens

J Hancox, D Spalton, C Heatley… - Journal of Cataract & …, 2006 - journals.lww.com
PURPOSE: To objectively measure the shift and refractive change of the 1CU accommodating
intraocular lens (IOL)(HumanOptics) and compare them to that of a monofocal AcrySof …

Fellow eye comparison between the 1CU accommodative intraocular lens and the Acrysof MA30 monofocal intraocular lens

CJ Heatley, DJ Spalton, J Hancox, A Kumar… - American journal of …, 2005 - Elsevier
PURPOSE: To examine the near visual clinical performance of an accommodative intraocular
lens (IOL) when compared with a standard monofocal IOL in a fellow eye comparison. …

Fellow-eye comparison of posterior capsule opacification rates after implantation of 1CU accommodating and AcrySof MA30 monofocal intraocular lenses

J Hancox, D Spalton, C Heatley, H Jayaram… - Journal of Cataract & …, 2007 - Elsevier
PURPOSE: To measure posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG)
capsulotomy rates between the AcrySof MA30 intraocular lens (IOL) (Alcon) and the 1CU …

The effectiveness of non-pharmaceutical interventions in containing epidemics: a rapid review of the literature and quantitative assessment

J Cheatley, S Vuik, M Devaux, S Scarpetta, M Pearson… - MedRxiv, 2020 - medrxiv.org
The number of confirmed COVID-19 cases has rapidly increased since discovery of the disease
in December 2019. In the absence of medical countermeasures to stop the spread of the …