Percutaneous implantation of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position: early phase 1 results from an international …

D Kenny, ZM Hijazi, S Kar, J Rhodes, M Mullen… - Journal of the American …, 2011 - jacc.org
Objectives : The purpose of this study was to evaluate the safety and effectiveness of the
Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the …

Coarctation of the aorta: from fetal life to adulthood

D Kenny, ZM Hijazi - Cardiology journal, 2011 - journals.viamedica.pl
Coarctation of the aorta was once viewed as a simple discrete narrowing of the aortic isthmus
that could be ‘cured’by surgical intervention. It is now clear that this condition may:(1) affect …

Transcatheter tricuspid valve-in-valve implantation for the treatment of dysfunctional surgical bioprosthetic valves: an international, multicenter registry study

…, S Shahanavaz, C Moretti, MR Hainstock, DP Kenny… - Circulation, 2016 - Am Heart Assoc
Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for
tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) …

Relative risk factors for cardiac erosion following transcatheter closure of atrial septal defects: a case–control study

DB McElhinney, MD Quartermain, D Kenny… - Circulation, 2016 - Am Heart Assoc
Background— Transcatheter closure of secundum atrial septal defects (ASD) using the
Amplatzer septal occluder is generally safe and effective, but erosion into the pericardial space …

Early clinical experience with a novel self‐expanding percutaneous stent‐valve in the native right ventricular outflow tract

QL Cao, D Kenny, D Zhou, W Pan… - Catheterization and …, 2014 - Wiley Online Library
Introduction Balloon expandable transcatheter pulmonary valve systems are not applicable
to the large majority of patients with chronic severe pulmonary regurgitation (PR) following …

3-year outcomes of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position from the COMPASSION multicenter clinical trial

D Kenny, JF Rhodes, GA Fleming, S Kar… - JACC: Cardiovascular …, 2018 - jacc.org
Objectives : This study provides the 3-year follow-up results of the COMPASSION (Congenital
Multicenter Trial of Pulmonic Valve Regurgitation Studying the SAPIEN Transcatheter …

Transcatheter pulmonary valve replacement with the sapien prosthesis

…, MH Martin, B Keeshan, JD Asnes, D Kenny… - Journal of the American …, 2020 - jacc.org
Background There are limited published data focused on outcomes of transcatheter pulmonary
valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. Objectives …

Correction of sinus venosus atrial septal defects with the 10 zig covered Cheatham‐platinum stent–An international registry

…, MM Salem, K Walsh, D Kenny… - Catheterization and …, 2021 - Wiley Online Library
Background Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new
technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior …

[PDF][PDF] Medium-term results of percutaneous pulmonary valve implantation using the Venus P-valve: international experience

…, M Kappanayil, I Sakidjan, KP Walsh, D Kenny… - …, 2019 - researchgate.net
Aims: The aim of this study was to assess the international procedural and short-term to
midterm experience with the new percutaneous Venus P-valve. Methods and results: …

Balloon expandable stent implantation for native and recurrent coarctation of the aorta—prospective computed tomography assessment of stent integrity, aneurysm …

S Chakrabarti, D Kenny, G Morgan, SL Curtis… - Heart, 2010 - heart.bmj.com
Background Stenting for aortic coarctation is known to be effective in the medium term.
Aneurysm formation following stent implantation is a recognised complication. However, data …